Devices for registering and analysing quality and parameters of power supply

The wide range of devices offered by our company enables the user to examine all important phenomena occurring in one-phase and three-phase networks. The devices and instruments measure and register : current, voltage, powers, power factors, energies, harmonics distortion factors harmonics, pulsation factors, voltage drops and breaks and tens of other parameters.
The collected data can be printed on the printer or transmitted to the PC computer for further processing. Registering devices we manufacture as a standard are equipped with the software enabling wide-range analysis of measured parameters, with the particular regard for needs of the professional power engineering.
Moreover in our offer one can find a wide choice of clamp-type current transformers and flexible loop current probes which can be used together with the above described registering and analyzing devices.

In order to be able to review information cards of our products in PDF format you need the program: Pobierz Adobe Acrobat Reader 


!NEW! Registering devices for electrical parameters type REM-211 and REM-221

REM-221

 

The registering devices are manufactured as portable; they enable measurement and registration of basic electric parameters in three-phase low voltage systems. REM-211 it is the registering device for rms values of phase voltages and frequency, while REM-221 registers additionally rms values of phase currents, active powers, reactive powers and active energies independently for each of the phases. Registering devices monitor, store in memory and analyze events occurring in the network in order to detect disturbances, diagnose failure states, determine the reasons for failure states etc. besides they can average measurement results, which is necessary for the supply quality assessment done in the conformity with the EN 50160 standard. Software solutions enable the automatic generation of the relevant supply quality assessment report. Construction of both devices enables their installation directly on the pillar, in the place where the measurements are carried out.
Full technical data can be found in information leaflet.

These devices are particularly useful for:

  • Detecting illegal electrical energy inputs.

  • Checking and monitoring quality of supplied electrical energy.

  • Analyzing demand for electrical energy.

  • Preventing overheating of insulation of cables and conductors.

  • Detecting breaks and overvoltages in the network.

  • Measuring starting currents for various devices and apparatuses.

Special housing with high leaktightness enables installation of these devices directly on the pillar in the place where measurements are carried out.

 

Download the information card in *.pdf format

Load the information card in PDF format for clamp-type transformers and flexible loop current probes designed for using together with REM-221 registering devices.


Power supply quality analysing device with harmonics analysis type REM-370

REM-370

SELECTED TECHNICAL DATA:

Measurements in conformity with standard: EN 50160 or standard defined by user !
Number of phases: 1 or 3
Memory capacity: 3MB
Interface: RS-232 optic interface
Power supply: 110, 230 lub 380V from measuring conductors
Reserve supply: from battery of accumulators
Operation without power supply: 2hours (memory 1 year)
Housing protection: industrial, IP52
Measurements: 137 x 132 x 138mm

This modern device can register several hundred network parameters and examine energy quality in accordance with EN 50160 standard. Especially interesting are unique features of this device such as detection of micro-breaks in power supply, change in the recording speed and in the memory record configuration after exceeding some preset limit value or statistic classification of average values. Full specification of registered parameters is included in the information card of the device. Moreover the device can be used together with optional miniature printer (which does not require external PC computer for its operation). This printer can print the report of supply quality conformance with EN 50160 standard or the report of measured parameters momentary values, without interrupting the registration of measurements results into the device memory.

Download the information card in *.pdf format

Load the information card in PDF format for clamp-type transformers and flexible loop current probes designed for using together with REM-221 registering devices.
Download mini printer MDI-57 information card in *.pdf format


 


Multi-phase meter for voltage breaks duration LCZN-01

LCZN-01

WYBRANE DANE TECHNICZNE

Ilość monitorowanych linii: 9
Pojemność liczników: 9999,99 godzin
Zabezpieczenie kasowania liczników: kod czterocyfrowy
Częstotliwość testu napięcia: co 1s

Multi-phase meter for voltage breaks duration LCZN-01 is designed for monitoring supply continuity (voltage presence) in low voltage networks.
This device monitors independently up to nine lines (three 3-phase four-conductor circuits or nine 1-phase circuits), indicating the duration of normal line operation (when U>150 V) and the duration of voltage drops and breaks in supply U<150 V) on two separate 6-digit displays.
On the basis of these indications one can asses the performance efficiency of technical services responsible for the energy supply continuity, and by this mobilize them to react fast for all the arising problems, which leads to minimizing losses caused by breaks in electrical energy supply. It is also possible to use this device for registering and controlling work time of machines in industry.
Resetting the counters is possible after entering four-digit access code.
The meter has got the convenient module-type housing enabling its fast installation on the standard DIN-bus.

Download the information card in *.pdf format

 

our offer

Time nets - master clocks, autonomous and slave clocks, analog and digital

Devices for time synchronization

Power analysers for registering and analysing quality of power supply

Indicators of fault spot in the MV cable power networks

 
Main page
How to contact us
 
Main page How to contact us  

 Copyright © 2006 by Time-Net